Manufactured within a rugged HDPE chassis this 125A distribution unit is designed for use on large events and concerts. Made in Britain 125A three phase input with link output Earth stud Input: 125A type 4 distro in 125A 3PH appliance inlet with neon indicators protected by an overall 125A 4-Pole MCB Outputs:1 x 63A 3PH panel socket with neon indicators protected by:1 x 63A 4-Pole MCB Digital variable switchable RCD 3 x 32A 3PH panel sockets with neon indicators protected by:3 x 32A 4-Pole MCB Digital variable switchable RCD 6 x 32A 1PH panel sockets with neon indicators protected by:6 x 32A 2-Pole 30mA RCBO’s 12 x 16A 1PH panel sockets with neon indicators protected by:12 x 16A 2-Pole 30mA RCBO’s